335 research outputs found

    Development of a fast curing tissue adhesive for meniscus tear repair

    Get PDF
    Isocyanate-terminated adhesive amphiphilic block copolymers are attractive materials to treat meniscus tears due to their tuneable mechanical properties and good adhesive characteristics. However, a drawback of this class of materials is their relatively long curing time. In this study, we evaluate the use of an amine cross-linker and addition of catalysts as two strategies to accelerate the curing rates of a recently developed biodegradable reactive isocyanate-terminated hyper-branched adhesive block copolymer prepared from polyethylene glycol (PEG), trimethylene carbonate, citric acid and hexamethylene diisocyanate. The curing kinetics of the hyper-branched adhesive alone and in combination with different concentrations of spermidine solutions, and after addition of 2,2-dimorpholinodiethylether (DMDEE) or 1,4-diazabicyclo [2.2.2] octane (DABCO) were determined using FTIR. Additionally, lap-shear adhesion tests using all compositions at various time points were performed. The two most promising compositions of the fast curing adhesives were evaluated in a meniscus bucket handle lesion model and their performance was compared with that of fibrin glue. The results showed that addition of both spermidine and catalysts to the adhesive copolymer can accelerate the curing rate and that firm adhesion can already be achieved after 2 h. The adhesive strength to meniscus tissue of 3.2–3.7 N was considerably higher for the newly developed compositions than for fibrin glue (0.3 N). The proposed combination of an adhesive component and a cross-linking component or catalyst is a promising way to accelerate curing rates of isocyanate-terminated tissue adhesives

    Amphiphilic poly(ether ester amide) multiblock copolymers as biodegradable matrices for the controlled release of proteins

    Get PDF
    Amphiphilic poly(ether ester amide) (PEEA) multiblock copolymers were synthesized by polycondensation in the melt from hydrophilic poly(ethylene glycol) (PEG), 1,4-dihydroxybutane and short bisester-bisamide blocks. These amide blocks were prepared by reaction of 1,4-diaminobutane with dimethyl adipate in the melt. A range of multiblock copolymers were prepared, with PEG contents varying from 23-66 wt %. The intrinsic viscosity of the PEEA polymers varied from 0.58-0.78. Differential scanning calorimetry showed melting transitions for the PEG blocks and for the amide-ester blocks, suggesting a phase separated structure. Both the melting temperature and the crystallinity of the hard amide-ester segments decreased with increasing PEG content of the polymers. The equilibrium swelling ratio in phosphate buffered saline (PBS) increased with increasing amount of PEG in the polymers and varied from 1.7 to 3.7, whereas the polymer that contained 66 wt % PEG was soluble in PBS. During incubation of PEEA films in PBS, weight loss and a continuous decrease in the resulting inherent polymer viscosity was observed. The rate of degradation increased with increasing PEG content. The composition of the remaining matrices did not change during degradation. A preliminary investigation of the protein release characteristics of these PEEA copolymers showed that release of the model protein lysozyme was proportional to the square root of time. The release rate was found to increase with increasing degree of swelling of the polymers

    Surface Curvature Differentially Regulates Stem Cell Migration and Differentiation via Altered Attachment Morphology and Nuclear Deformation

    Get PDF
    Signals from the microenvironment around a cell are known to influence cell behavior. Material properties, such as biochemical composition and substrate stiffness, are today accepted as significant regulators of stem cell fate. The knowledge of how cell behavior is influenced by 3D geometric cues is, however, strongly limited despite its potential relevance for the understanding of tissue regenerative processes and the design of biomaterials. Here, the role of surface curvature on the migratory and differentiation behavior of human mesenchymal stem cells (hMSCs) has been investigated on 3D surfaces with well-defined geometric features produced by stereolithography. Time lapse microscopy reveals a significant increase of cell migration speed on concave spherical compared to convex spherical structures and flat surfaces resulting from an upward-lift of the cell body due to cytoskeletal forces. On convex surfaces, cytoskeletal forces lead to substantial nuclear deformation, increase lamin-A levels and promote osteogenic differentiation. The findings of this study demonstrate a so far missing link between 3D surface curvature and hMSC behavior. This will not only help to better understand the role of extracellular matrix architecture in health and disease but also give new insights in how 3D geometries can be used as a cell-instructive material parameter in the field of biomaterial-guided tissue regeneration.Peer reviewe

    Biocompatibility and degradation comparisons of four biodegradable copolymeric osteosynthesis systems used in maxillofacial surgery:A goat model with four years follow-up

    Get PDF
    Applying biodegradable osteosyntheses avoids the disadvantages of titanium osteosyntheses. However, foreign-body reactions remain a major concern and evidence of complete resorption is lacking. This study compared the physico-chemical properties, histological response and radiographs of four copolymeric biodegradable osteosynthesis systems in a goat model with 48-months follow-up. The systems were implanted subperiosteally in both tibia and radius of 12 Dutch White goats. The BioSorb FX [poly(70LLA-co-30DLLA)], Inion CPS [poly([70-78.5]LLA-co-[16-24]DLLA-co-4TMC)], SonicWeld Rx [poly(DLLA)], LactoSorb [poly(82LLA-co-18GA)] systems and a negative control were randomly implanted in each extremity. Samples were assessed at 6-, 12-, 18-, 24-, 36-, and 48-month follow-up. Surface topography was performed using scanning electron microscopy (SEM). Differential scanning calorimetry and gel permeation chromatography were performed on initial and explanted samples. Histological sections were systematically assessed by two blinded researchers using (polarized) light microscopy, SEM and energy-dispersive X-ray analysis. The SonicWeld Rx system was amorphous while the others were semi-crystalline. Foreign-body reactions were not observed during the complete follow-up. The SonicWeld Rx and LactoSorb systems reached bone percentages of negative controls after 18 months while the BioSorb Fx and Inion CPS systems reached these levels after 36 months. The SonicWeld Rx system showed the most predictable degradation profile. All the biodegradable systems were safe to use and well-tolerated (i.e., complete implant replacement by bone, no clinical or histological foreign body reactions, no [sterile] abscess formation, no re-interventions needed), but nanoscale residual polymeric fragments were observed at every system's assessment

    In vitro and biomechanical screening of polyethylene glycol and poly(trimethylene carbonate) block copolymers for annulus fibrosus repair

    Get PDF
    Herniated intervertebral discs (IVDs) are a common cause of back and neck pain. There is an unmet clinical need to seal annulus fibrosus (AF) defects, as discectomy surgeries address acute pain but are complicated by reherniation and recurrent pain. Copolymers of polyethylene glycol with trimethylene carbonate (TMC) and hexamethylene diisocyanate (HDI) end-groups were formulated as AF sealants as the HDI form covalent bonds with native AF tissue. TMC adhesives were evaluated and optimized using the design criteria: stable size, strong adherence to AF tissue, high cytocompatibility, restoration of IVD biomechanics to intact levels following in situ repair, and low extrusion risk. TMC adhesives had high adhesion strength as assessed with a pushout test (150kPa), and low degradation rates over 3weeks in vitro. Both TMC adhesives had shear moduli (220 and 490kPa) similar to, but somewhat higher than, AF tissue. The adhesive with three TMC moieties per branch (TMC3) was selected for additional in situ testing because it best matched AF shear properties. TMC3 restored torsional stiffness, torsional hysteresis area and axial range of motion to intact states. However, in a failure test of compressive deformation under fixed 5 degrees flexion, some herniation risk was observed with failure strength of 5.9MPa compared with 13.5MPa for intact samples; TMC3 herniated under cyclic organ culture testing. These TMC adhesives performed well during in vitro and in situ testing, but additional optimization to enhance failure strength is required to further this material to advanced screening tests, such as long-term degradation. Copyright (c) 2016 John Wiley & Sons, Ltd

    Microbial biofilm growth vs. tissue integration: "the race for the surface" experimentally studied

    Get PDF
    Biomaterial-associated infections constitute a major clinical problem. Unfortunately, microorganisms are frequently introduced onto an implant surface during surgery and start the race for the surface before tissue integration can occur. So far, no method has been forwarded to study biofilm formation and tissue integration simultaneously. The aim of this study is to describe an in vitro method to investigate this “race for the surface”. First, a suitable growth medium was prepared that allowed both bacterial and tissue growth in a parallel plate flow chamber. Staphylococci were deposited on the glass bottom plate of the flow chamber in different surface densities, after which U2OS osteosarcoma cells were seeded. U2OS cells did not grow in the absence of flow, possibly due to poisoning by bacterial endotoxins, but under flow both staphylococci and U2OS cells grew. The number of adhering cells and area per spread cell were determined after 48 h in relation to the initial number of bacteria present. Both the number and spread area per cell decreased with increasing density of adhering staphylococci. This demonstrates that the outcome of the race for the surface between bacteria and tissue cells is dependent on the number of bacteria present prior to cell seeding.\u
    • …
    corecore